Application of data center and UPS
Data Center Overview:
Data centers are globally collaborative specific networks of devices used in IntraTransfer, accelerate, display, calculate, and store data and information on the network infrastructure. Most electronics in the data center are driven by low-DC power supplies.
The emergence of data centers has led peoples understanding from the quantitative and structured world to the uncertain and unstructured world. It will gradually become a part of the infrastructure of modern society, just like transportation and network communication, and then have a positive impact on many industries. However, the development of data centers should not only rely on experience, but also really combine with practice to promote the data centers to play a real value role and promote the rapid social change.
A Schematic diagram of the UPS system
-
uninterruptible power supplyUPS is an uninterruptible power supply, which is an uninterruptible power supply containing energy storage devices. It is mainly used to provide uninterrupted power supply for someequipment with high requirements on power supply stability requirements.
-
working principleWhen the mains power input is normal, the UPS supplies the mains power after voltage stabilizationLoad use, the UPS at this time is an AC currentThe regulator also charges the battery; when the mains power is interrupted (accident outage), the UPS immediately passes the direct current of the batteryThe method of inverter switching and conversion continues to supply 220V or 380V to the loadAC to keep the load working and keep the load softThe hardware is not damaged.UPSEquipment usually provides protection for either too high or too low voltage.
-
UseIn the data center, the parallel redundant UPS system composed of dual transform UPS single unit is generally used. When the datacenter load is for dual power supply, the parallel redundant UPS is used to form the dual bus UPS power supply system.
Features of lithium battery UPS
The lithium battery UPS system, combined with the characteristics of high energy density, small footprint, long service life, high safety performance, convenient operation and maintenance mode, can provide high quality power guarantee for the data center, IT room and major key loads in the fields of communication, IT and industrial fields.
-
protection functionsThe charge and discharge cycle times can reach 5000 times, and the service life can reach 10 years. The BMS battery management system has perfect protection functions (short circuit, overcurrent, overcharge, overdischarge, overtemperature, etc.)
-
protection controlLithium UPS system has three-level protection control, UPS and BMS realize the whole monitoring of dual lithium battery backup system
-
standardized designPACK module standardized design can be freely combined, and the volume and weight are 1 / 3 of lead-acid battery, which is more suitable for spatially limited application scenarios
parameter list
3Y3T3R00 | 3YST4R00 | 33Y5T0RO3 | 3Y3T6R00 | 3Y3T8R00 | 33Y1T0R | 33Y1T2R00 | ||
UPS | Input voltage range (Vac) | 228~477 | ||||||
Input frequency range (Hz) | 50 / 60 ± 10% (± 5 optional) | |||||||
Input Current | Full load of THDi 2% | |||||||
Harmonics (THDi) | ||||||||
Output power factor | Up to 1.0 | |||||||
Output voltage (Vac) | 380 ± 1% (400 ± 1%, 415 ± 1% optional) | |||||||
Output (wave TH shape D lost v) truth | <1% (linear load), <3% (nonlinear load) | |||||||
overload capacity | Load 105%: long-term operation; 105% <110% load: bypass after 60 min; 110% <1 load 25%: Maintain bypass after 10min; 125% <150% load: maintain | |||||||
bypass after 1min | ||||||||
overall | Up to 97% | |||||||
efficiency | ||||||||
charging current (A) | 25~100 | 25~200 | ||||||
CI | Support RS232 / 485, MODBUS, dry contact communication (SNMP selectable) | |||||||
working temperature (℃) | -5~40 | |||||||
relative humidity | 0~95%, with no condensation | |||||||
(Wide, foot, deep, inch, height) | 1000×900×1950 | 1400×900×1950 | 1900×900×1950 | 3000×900×1950 | ||||
(mm) | ||||||||
weight (kg) | 700 | 1100 | 1300 | 2400 | ||||
lith ium cell | System nominal voltage (Vdc) | 512 | ||||||
Mode nominal voltage (Vdc) | 51.2 | |||||||
Model nominal capacity (Ah) | 50/100/200 | |||||||
System Voltage Range (Vdc) | 448~584 | |||||||
Cell (Ah) | 50/100/200 | |||||||
charging current (A) | ≤1C | |||||||
discharge current (A) | 4C/1C | |||||||
heat management | forced air cooling | |||||||
Mode weight (kg) | 35/70/80 | |||||||
(Wide module depth ruler inch height)(mm) | 442×690×106/442×800×150/442×810 × 127 | |||||||
(Wide pool deep cabinet tall) (mm) | 600×800×2000/600×1000×2000 |
Features of lithium battery UPS
In addition to data center lithium UPS, there are more commonly used backup, online UPS, mainly used in government, education, finance, communication, insurance, transportation, tax, securities, and other
fields.
Lead-acid batteries in energy storage applications are still mainly used in these areas
Three in single out series three in three out series parameter list
YTR3320 | YTR3330 | YTR3340 | ||
impor t chara cteri stic | Power supply system | 3W+N+PE | ||
Input voltage range (Vac) |
L-N:80~275 | |||
Input frequency range (Hz) | 40~70 | |||
Bypass input voltage range (Vac) | ± 20%, ± 15%, ± 10% can be set (default ± 20%) | |||
Input power factor | >0.99 | |||
Input current harmonics | <3% (nonlinear load) | |||
cell (Vdc) | ± 144- ± 240 Adjustable (default: ± 192) | |||
outpu t chara cteri stic | Output power factor | 1.0 | ||
voltage (Vac) | L-N: 220 / 230 / 240 ± 1% (default 220) | |||
frequency (Hz) | mains normal, tracking bypass input; mains abnormal, local 50 ± 0.1 or 60 ± 0.1 | |||
Wwaveform distortion (THD v) | <1% (linear load), <4% (nonlinear load) | |||
overall efficiency | Up to 96% | |||
overload capacity | Load 105%: long-term operation; 105% <110%: 60 minutes to bypass; 110% <130%: 10 minutes to turn Bypass; 130% <155%: After 1 minute; bypass on load> 155% | |||
else
charac terist ic |
DC start function | possess | ||
Communication function | Standard RS485,1 input dry contact and 3 output dry contact | |||
Warning function | Input abnormality, battery low voltage, overload, fault, etc | |||
defencive function | Output short circuit protection, output overvoltage / undervoltage protection, overload protection, over temperature protection, battery undervoltage protection, etc | |||
working temperature | 0~40℃ |